A fire hydrant is a device, which is connected to the water supply and provides convenient water intake from it. The main function of such equipment is, that it acts as a point, to which the fire hoses are joined, used to eliminate various sources of ignition. Ancillary function of GHG - reclamation activities.
Installation, maintenance and operation of fire hydrants must be carried out in accordance with established rules
What is a fire hydrant? These devices are indispensable in firefighting. They take water from the water supply, and then pass it to the fire hoses under a certain pressure. The fire hydrant can be cast iron or steel. PG, usually, are used in suburban areas and are classified according to a simplified version of the installation into two main varieties:
What are underground fire hydrants? Underground devices are the most popular and today they are the most commonly used to provide fluid supply for various needs.. Their popularity is due to ??team, that they provide uninterrupted supply of liquid from the water supply.
Consider the basic rules for placing such equipment in wells:
Hydrants are above ground and underground, the first are located on the ground and do not require a well device
pay attention! If such a device is used very often, then it needs to organize a fire line. This line is installed around the perimeter of the well. The fire line consists of pipelines and hoses, which are located on the perimeter of the required strategic objects.
To simplify GHG installation, usually, the corresponding instruction is attached to it. This technical document includes three main provisions:
To study the structure of GHG, you can see the designation of the fire hydrant in the drawing. In the drawings, usually, all structural elements of this device are marked.
What are overhead fire hydrants? Fireless fire hydrant is used much less often and is more complex (from a constructive point of view) device. Usually, such GHGs are mounted on manholes, but, there are devices, installed on the soil surface. A water source is required to organize such water intake equipment, which location should be nearby.
In winter, the above-ground fire hydrant must be drained, otherwise the frozen water inside it will render the device unusable. Many overhead models have an automatic drain function, which is very convenient.
The underground hydrant is not so convenient in work, as overhead, but it does not require draining the water in winter
Experts recommend turning to professionals for this, to calculate the required parameters of the well, in which the water intake device will be located. However, if desired, you can make all the calculations yourself. But such work is difficult and quite responsible. There are several basic requirements for such wells, which are worth paying attention to:
Guided by the above requirements and performing the necessary calculations, you can install the well yourself.
Installation of GHGs must be carried out in accordance with certain rules and regulations, which are specified in the relevant technical documentation.
Type and number of hydrants, installed on an object, regulated by the rules of SNiP
Consider some factors, which must be taken into account before installing a water intake device:
Consider the basic requirements, which are put forward by aboveground GHG:
Importantly! The organization of a fire hydrant on the roadway is strictly prohibited.
In turn, underground hydrants must be installed, focusing on such requirements:
The hydrant must be in place, where firefighters are provided with free access at any time
Basic rules, which must be observed for the normal operation of the GHG, sound like this:
The principle of operation of the fire hydrant is quite simple. To use it, follow these steps:
After operation of the device all above-stated actions are made in opposite sequence. Liquid residues must be drained from the GHG.
To events, which are included in the maintenance of such equipment, include:
Testing of fire-fighting equipment is a necessary measure, which determine the professional suitability of a device. Such inspections are aimed at detecting problems or failure of fire equipment. During the test, the rapid start-up of water and, in accordance, the pressure in the water intake device is pumped.
Testing of fire hydrants, according to the rules, are held every six months
Trial, aimed at checking the pressure, are performed in the case, if there is a special stand, and the device measures the pressure (pressure gauge). The accuracy class of the measuring instrument must be equal to 1,5. Tests of fire hydrants are made taking into account all necessary regulatory documentation (GUEST 15150).
Importantly! Tests of fire hydrants should be carried out at least 1 times in 6 months.
The following structural elements of fire-fighting equipment must be inspected during the GHG strength test:
Fire hydrant drainage and range are calculated during maximum water consumption. After conducting all relevant inspections and inspections of fire equipment, an act of testing of above-ground or underground fire hydrants is drawn up. This act is passed to the owner of the product, to which the GHG belongs and remains with him until the next tests.
A sewing machine is an indispensable tool for many housewives.. Ее наличие среди бытовых принадлежностей дает возможность…
Fuel truck - special equipment, which is intended for the transportation of refined products and fuels and lubricants. Она представляет…
If you are determined to learn the acoustic guitar, варто одразу купувати якісну продукцію в надійному…
Face masks are one of the most popular face care products.. After all, они становятся…
"The key to a woman's heart is an unexpected gift at the wrong time", - says Forrester in the film "in…
Modern hairpins can not only fulfill their immediate obligations, но и сделать образ девушки индивидуальным…